What was found
NR 2 ENG PARAMETERS FLUCUATING. CLEARED MOISTURE TRAP OF LARGE AMOUNT OF WATER. SERVICED FUEL CONTROL BELLOWS, RAN ENG AT CRUISE AND T/O POWER FOR EXTENDED PERIOD, OPS GOOD. REF LOG PG 179027 ITEM I P.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENG PARAMETERS FLUCUATING. CLEARED MOISTURE TRAP OF LARGE AMOUNT OF WATER. SERVICED FUEL CONTROL BELLOWS, RAN ENG AT CRUISE AND T/O POWER FOR EXTENDED PERIOD, OPS GOOD. REF LOG PG 179027 ITEM I P.