What was found
LAVATORY AREA FLOORBEAM BS 328 AND BBL 48 RIGHT AREA HAS CORROSION. INSTALL FLOORBEAM REPAIR PER 51-40-4. SIZE OF REPAIR 35 X 9 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LAVATORY AREA FLOORBEAM BS 328 AND BBL 48 RIGHT AREA HAS CORROSION. INSTALL FLOORBEAM REPAIR PER 51-40-4. SIZE OF REPAIR 35 X 9 INCH.