What was found
FWD BAGGAGE COMPT S-20L AT BS 500 WHERE CLIP ATTACHED TO STRINGER HAS A PIN HOLE AND SUSPECTED CORROSION. CUT OUT DAMAGED AREA PER SRM 53-10-3. TREATED AND PRIMED AREA PER SRM 51-10-2. INSTALLED REPAIR PER SRM 53-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.