What was found
DURING C CHECK, FOUND RIGHT WING LOWER PANEL JUST O/B OF NR 5 FLAP TRACK DAMAGED ON THE INSIDE SURFACE. INSTALLED BOND REPAIR PER 727 SRM 51-30-2 AND 51-40-6, SIZE OF REPAIR 8 X 10 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C CHECK, FOUND RIGHT WING LOWER PANEL JUST O/B OF NR 5 FLAP TRACK DAMAGED ON THE INSIDE SURFACE. INSTALLED BOND REPAIR PER 727 SRM 51-30-2 AND 51-40-6, SIZE OF REPAIR 8 X 10 INCHES.