What was found
RT WING (TOP) PANEL JUST AFT OF APU EXHAUST DELAMINATED. INTERIM REPAIR INSTALLED PER AERONAUTICAL SOLUTIONS 00-0051R. COMPLETE PREM REPAIR. REMOVED APU EXHAUST DUCT PER M/M 49-80-0. REMOVED PANEL PER SRM 51-30-2 AND ROUTED TO F/G SHOP FOR REPAIR. INSTALLED BONDED REPAIR TO PANEL PER SRM 51-40-6. INSTALLED PANEL PER SRM 51-30-2. SEALED EDGES PER SRM 51-20-4. RE-INSTALLED APU EXHAUST DUCT PER M/M 49-80-00.