As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO BAY FRAME, STA 520 HAS CRACKED REPAIR AT INNER I/B FLANGE OVER STA 25 LT. REMOVED FLOOR SUPPORT STA 505 TO 530 OVER STR 26 LT FOR ACCESS PER SRM 51-30-2. REMOVED DOUBLER REPAIR FWD CARGO BAY FRAME STA 520 AT INNER I/B FLANGE OVER STR 25 LT PER SRM 51-30-2.INSTALLED NEW DOUBLER REPAIR PER SRM 53-10-1. ALODINED AND PRIMED PER SRM 51-10-2.