What was found
AT C-CHECK, AFT BAGGAGE COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA 1360.000 L-35R. REMOVED FASTENERS FROM AFFECTED AREA, FABRICATED DOUBLER. INSTALLED FLOOR DOUBLER WITH FASTENERS AND RIVETS IAW SRM 53-2-0 PG 12 2BA AND 2B. WORK DONE ON NONE ROUTINE 5586.