What was found
MAIN CARGO SUB FLOOR STA 615.000 BL 54 RT CRACKED 1 INCH. REMOVED FASTENERS PER SRM 51-1-21. CUT OUT DAMAGED AREA PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO SUB FLOOR STA 615.000 BL 54 RT CRACKED 1 INCH. REMOVED FASTENERS PER SRM 51-1-21. CUT OUT DAMAGED AREA PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21.