What was found
FWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 100.00 L-33 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED AREA PER SRM 51-1-8. INSTALLED NEW ANGLE PER SRM 51-1-21.