As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CARGO SUB FLOOR STA 420.00 BL 17 RT CRACKED 2 INCHES. REMOVED FASTENERS PER SRM 51-1-21. CUT DAMAGED AREA PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21 WITH NEW FASTENERS.