As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT BAGGAGE COMPT FLOOR SUPPORT ANGLE FRAME CRACKED .5 INCH AT STA 1460.0. REMOVED FASTENERS PER SRM 51-1-21 PG 1. STOP DRILLED PER SRM 53-2-0 FIG 1B. FABRICATED ANGLE PER SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B PG 1 & 2. INSTALLED ANGLE WITH NEW FASTENERS PER SRM 51-1-21 PG 1.