What was found
FWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 580.00 L-35 RT. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 580.00 L-35 RT. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21.