What was found
FWD BAGGAGE COMPT FRAME REINFOCING ANGLE CRACKED AT STA 140.00 L35-36 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE PER SRM 51-1-21.