As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 380.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEW FASTENERS PER SRM 51-1-21.