What was found
FWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED .5 INCH AT STA 520.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEW FASTENERS PER SRM 51-1-21.