What was found
LEFT WING T/E FLAP LINKS AND STRUCTURE RIB CRACKED AT STA 19.000. STOP DRILLED PER SRM 57-2-0. FABRICATED ANGLE PER SRM 52-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE PER SRM 57-20-0.