What was found
RIGHT MLG W/W LOWER PART RIGHT SIDE RIB CRACKED 1 INCH AT STA 874.000. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT MLG W/W LOWER PART RIGHT SIDE RIB CRACKED 1 INCH AT STA 874.000. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-0.