What was found
AT C CK; WING CENTER SECTION AREA UNDER CABIN FLOOR FITTING CRACKED 2 INCHES AT STA 834.00 L-22 LT. REMOVED CRACKED FITTING IAW SRM 51-1-20D, PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. INSTALLED NEW FITTING IAW SRM 51-1-20D, PG 9. REF: N/R 1622.