What was found
RT FUSELAGE FWD OF LOWER CARGO DOOR FRAME 1383 SKIN SURFACE HAS A DENT (ADJACENT AFT OF ICE LIGHT). E&E COMP, RT AFT OF AC BATTS, REPOSITIONED FOR SM ACCESS, RELAY BOX 251VU AND 252VU PER A300 MM 25-54-00. NO CANNON PLUGS DISCONNECTED. CUT OUT GOUGED/DAMAGED AREA APPROX 1 X 3.5 INCHES IAW A300 SRM-53-10-10. BLENDED GOUGE, OUT OF LIMITS IAW A300 SRM 53-10-10. FABRICATED DOUBLER AND TRIPLER. DRILLED AND COUNTERSUNK HOLES FOR FASTENERS. INSTALLED AND SEALED IAW A300 SRM 53-10-10 AND AVITAS RO AVHM 208RO-1. OK TO REINSTALL INSULATION BLANKETS AND REPOSITION ITEMS THAT WERE RELOCATED TO GAIN ACCESS FOR REPAIR INSIDE OF E & E COMPARTMENT IAW A300 SRM 53-10-10. REINSTALLED INSULATION BLANKET.