What was found
AFTER NR 2 START, APU BLEED IN CLOSE RESET, X-BLEED OPEN, NR 2 BLEED PRESS INDICATED 0 PSI, WITH NR 2 REGU FAULT LIGHT ILLUMINATED. RAN ABNORMAL PROCEDURE. STILL NO PRESSURE AND FAULT LIGHT RE-ILLUMINATED. EXERCISED AND RESET NR 2 ENG BLEED PRESSURE REGULATOR VALVE. OPS CHECKED OK PER MM 36-11-00.