What was found
UPON TAKEOFF, BRAKES HOT LIGHT CAME ON MWP, REJECTED TAKEOFF NR 3 BRAKE WAS INDICATING 300C AND BRAKE NR 7, 250C. R&R NR 7 BRAKE ASSY IAW MM 32-42-27. OPS & LEAK CHK OK. DEACTIVATED NR 3 BRAKE AND DEFERRED IAW MEL 32-42-09-1 CAT C, ENTERED AS DMI 5122. R&R NR 7 + NR 3 BRAKE ASSEMBLIES. DMI CLOSED. STATUS-CLOSED