What was found
AT C-CHECK, NR 1 ENG, LWR COWL O/B FWD AREA , INT ANGLE WORN AND BENT. REFERENCE: FWD OF 2ND U-BOLT, UPPER OF OIL SERVICE DOOR. REMOVED AND REPLACED INTERNAL ANGLE ON 1 ENG, LWR COWL O/B FWD OF 2ND U-BOLT ABOVE OIL SERVICE DOOR PER B727 SRM 51-30-2. MAT USED 2024-0-.050 28 X 31 PIECE PO 83110438LOT 7Y153Y05 HEAT TREATED TO 2024T3 PER GENERAL PROCESS SPECIFICATION 98PMSI247PS-01.