What was found
DURING STANDBY POWER CHECK EMERGENCY EXIT LIGHTS WILL NOT ILLUMINATE. REMOVED AND REPLACED EMERGENCY EXIT LIGHTS BATTERIES PER B727 MM 24-54-0. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING STANDBY POWER CHECK EMERGENCY EXIT LIGHTS WILL NOT ILLUMINATE. REMOVED AND REPLACED EMERGENCY EXIT LIGHTS BATTERIES PER B727 MM 24-54-0. OPS CHECK GOOD.