What was found
AT C-CK; FWD CARGO COMPT BEAM LOWER PART INTERCOSTAL CRACKED 2 INCHES (CEILING) AT STA 720.000 LBL 46. PERFORMED STOP DRILL IAW SRM 51-10-1 PG 6B, CLEANED TREATED AND PRIMED IAW SRM 51-10-2 PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 51-40 PG 1.