What was found
SKIN EXTERIOR HAS 0.250 INCH CRACK AT STA 1102, STR 4L. CUT AFFECTED AREA IAW SRM 53-30-3, PAGE 24. FABRICATED FILLER WITH ALCLAD 2024 T3 0.040 INCH, SRM 53-30-3, PAGE 24. FABRICATED DOUBLER WITH ALCLAD 2024 T3 0.063 INCH IAW SRM 53-30-3 PAGE 24. TREATED AND PRIMED IAW SRM 51-10-2, PAGE 1 AND 2. INSTALLED FILLER AND DOUBLER IAW SRM 53-30-3, PAGE 24.