What was found
C-CHECK, FORE FLAP CRACKED 2.0 INCH AT WBL 440. PERFORMED STOP DRILL IAW SRM 57-50-4, FIG 1. FABRICATED DOUBLER (ALCLAD 2024, T3, 0.050 INCH) IAW 57-50-4, FIG 1. CLEANED, TREATED AND PRIMED IAW 51-10-2, PAGE 1 AND 2. INSTALLED DOUBLER IAW SRM 57-50-4, FIG 4.