What was found
C-CHECK, FWD CARGO COMPARTMENT BEAM LOWER PART INTERCOSTAL BROKEN 1.0 INCH (CEILING) AT STA 540.000 LBL 43.0 INCH. PERFORMED STOP DRILL HOLE IAW SRM 51-10-1, PAGE 6. FABRICATED DOUBLER WITH ALCLAD 2024, T3, 0.032 INCH, 5 X 3 INCH IAW SRM 51-40, PAGE 1. TREATED AND PRIMED IAW SRM 51-10-2 PAGE 1 AND 2. INSTALLED DOUBLER IAW SRM 51-32-0, PAGE 1 AND 2. (NON-ROUTINE CARD 0915).