What was found
C-CHECK, MAIN CARGO COMPART CABLES PLACARD PROTECTIVE ANGLE CRACKED 0.50 INCH AT RBL 20 INCH BETWEEN STA 930.000 AND STA 940.000. PERFORMED STOP DRILL IAW SRM 51-10-1, PAGE 6B. FABRICATED DOUBLER (2024, T3, 0.032 INCH) IAW SRM 51-40, PAGE 1. CLEANED, TREATED, AND PRIMED IAW SRM 51-10-2, PAGE 1-2. INSTALLED DOUBLER IAW SRM 51-40, PAGE 1. (NON-ROUTINE CARD 0583).