What was found
AT C-CK; AFT CARGO FLOOR SUPPORT STRAP AT BS 991 LT TO RT HAS NUMEROUS ELONGATED HOLES AND DENTED. REMOVED OLD STRAP, CLEANED,TREATED AND PRIMED AREA IAW B727 SRM 51-10-2, FABRICATED AND INSTALLED NEW STRAP IAW B727 SRM 51-30-2 PG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CK; AFT CARGO FLOOR SUPPORT STRAP AT BS 991 LT TO RT HAS NUMEROUS ELONGATED HOLES AND DENTED. REMOVED OLD STRAP, CLEANED,TREATED AND PRIMED AREA IAW B727 SRM 51-10-2, FABRICATED AND INSTALLED NEW STRAP IAW B727 SRM 51-30-2 PG 1.