What was found
D-CHECK - CORROSION JUST INBD OF RT AFT LAV DUMP HOLE IN FLOOR JUST FWD OF STA 1183. CUT OUT DAMAGED AREA AT FLOOR WEB PER B727 SRM 51-40-2 PG 1-6. FABRICATED AND LOCATED HOLES IN DOUBLER PLATE AND FILLER PER B727 SRM 51-40-2 PG 1-6. ALODINED PER SRM 51-10-2 PG 1. PRIMED PARTS PER B727 SOPM 20-41-02 PG 1-20. (REF N/R 1252-02-001947)