What was found
ENG NR 1 SHUTDOWN - OIL QUANTITY AT 2 QUARTS WITH SLIGHT FLUCTUATION IN PRESSURE - 1 TO 2 POUNDS. FOUND STARTER PAD LEAKING. REMOVED STARTER, REPLACED GARLOCK SEAL & ASSOCIATED O-RINGS, REINSTALLED STARTER PER 80-10-00. PERFORMED RUN, NO LEAKS NOTED.