What was found
FWD CARGO COMPT-FLOOR SUPPORT ANGLE CRACKED .5 INCH AT STA 272.000, L33R. STOP DRILLED CRACK PER SRM 53-2-0 PG 2E-2F. FABRICATED ANGLE PER SRM 53020-0 PG 2E-2F. INSTALLED ANGLE PER SRM 53-2-0 PG 2E-2F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO COMPT-FLOOR SUPPORT ANGLE CRACKED .5 INCH AT STA 272.000, L33R. STOP DRILLED CRACK PER SRM 53-2-0 PG 2E-2F. FABRICATED ANGLE PER SRM 53020-0 PG 2E-2F. INSTALLED ANGLE PER SRM 53-2-0 PG 2E-2F.