AFT CARGO COMPT FLOOR LINING ATTACH ANGLE CRACKED 1 INCH BETWEEN STA 1340.000 AND L-31R. STOP DRILLED CRACK PER SRM 53-2-0 PG 2E. FABRICATED REINFORCING ANGLE PER SRM 53-2-0 PG 2E-2F. INSTALLED ANGLE PER SRM 53-20 PG 2E-2F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPT FLOOR LINING ATTACH ANGLE CRACKED 1 INCH BETWEEN STA 1340.000 AND L-31R. STOP DRILLED CRACK PER SRM 53-2-0 PG 2E. FABRICATED REINFORCING ANGLE PER SRM 53-2-0 PG 2E-2F. INSTALLED ANGLE PER SRM 53-20 PG 2E-2F.