What was found
CENTER WING BEAM LOWER SUPPORT ANGLE CRACKED 1 INCH AT STA 683 XCW 23 R. REMOVED CRACKED SUPPORT ANGLE PER SRM 51-1-20 PG 21. FABRICATED NEW SUPPORT ANGLE PER SRM 53-2-0 PG 1-2. INSTALLED NEW SUPPORT ANGLE PER SRM 51-1-20 PG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER WING BEAM LOWER SUPPORT ANGLE CRACKED 1 INCH AT STA 683 XCW 23 R. REMOVED CRACKED SUPPORT ANGLE PER SRM 51-1-20 PG 21. FABRICATED NEW SUPPORT ANGLE PER SRM 53-2-0 PG 1-2. INSTALLED NEW SUPPORT ANGLE PER SRM 51-1-20 PG 9.