MAIN CARGO COMPT SUBFLOOR CRACKED 1 INCH AT STA 1550 L-21 RT. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0 PG 1-2. INSTALLED NEW SUPPORT ANGLE PER SRM 51-1-20D PG 9.