What was found
RT MLG TRAPEZOIDAL LWR END, STOP DRILLED CRACK (6.125 IN ) CONTINUES .5 IN BEYOND STOP DRILL AT STA 896.12. STOP DRILLED CRACK (.375 DIA), INSPECTED WITH NDT, CRACK DOES NOT CONTINUE PER SEQ-LIM 0100070H 06-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT MLG TRAPEZOIDAL LWR END, STOP DRILLED CRACK (6.125 IN ) CONTINUES .5 IN BEYOND STOP DRILL AT STA 896.12. STOP DRILLED CRACK (.375 DIA), INSPECTED WITH NDT, CRACK DOES NOT CONTINUE PER SEQ-LIM 0100070H 06-20-01.