What was found
REAR PRESSURE BULKHEAD FITTING AT STA 1366 L17R CRACKED 1 IN.REMOVED CRACKED FITTINGPER SRM 51-1-20 PG 21.CLEANED TREATED AND PRIMED AREA PER SRM 51-1-8B.INSTALLED NEW FITTING PER SRM 51-1-20-D PG 9
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
REAR PRESSURE BULKHEAD FITTING AT STA 1366 L17R CRACKED 1 IN.REMOVED CRACKED FITTINGPER SRM 51-1-20 PG 21.CLEANED TREATED AND PRIMED AREA PER SRM 51-1-8B.INSTALLED NEW FITTING PER SRM 51-1-20-D PG 9