What was found
D-CHECK; FLT COMPT- ANGLE LINKED TO FLOORBEAM CORRODED STA 52 NEAR L-22R RBL 60. CUT OUT CORRODED AREA. FABRICATED FILLER IAW SRM 53-2-0 FIG 2. INSTALLED FILLER & DOUBLER (LT & RT).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
D-CHECK; FLT COMPT- ANGLE LINKED TO FLOORBEAM CORRODED STA 52 NEAR L-22R RBL 60. CUT OUT CORRODED AREA. FABRICATED FILLER IAW SRM 53-2-0 FIG 2. INSTALLED FILLER & DOUBLER (LT & RT).