What was found
C-CHECK - FWD CARGO COMPT SIDE WALL SUPPORT ANGLE CRACKED 1/2 INCH AT STATION 180 L-31 RT. CORRECTIVE ACTION: PERFORMED STOP HOLE, FABRICATED REINFORCING ANGLE (STEEL 301, 1/2 H, 0.032 INCH) AND INSTALLED IAW SRM 53-2-0, FIG. 1B. STATUS - CLOSED