What was found
C-CHECK - FWD CARGO COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA. 220 L-35 LT CORRECTIVE ACTION: PERFORMED STOP HOLE. FABRICATED REINFORCING ANGLE AND INSTALLED IAW SRM 53-2-3 FIG 10. STATUS-CLOSED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C-CHECK - FWD CARGO COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA. 220 L-35 LT CORRECTIVE ACTION: PERFORMED STOP HOLE. FABRICATED REINFORCING ANGLE AND INSTALLED IAW SRM 53-2-3 FIG 10. STATUS-CLOSED.