What was found
C-CHECK - FWD. CARGO COMPARTMENT - FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA 380 L-31R. REMOVED CRACKED ANGLE AT STA 380 L-31R IAW SRM 51-1-8 PAGE 21. FABRICATED ANGLE IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8, PAGE 12, 13. INSTALLED ANGLE IAW SRM 51-1-20D PAGE 9. STATUS-CLOSED.