What was found
C-CHECK - FWD CARGO COMPARTMENT - FLOOR SUPPORT ANGLE CRACKED 1/2 INCH AT STA 360.000 L-33R. PERFORMED STOP HOLE IAW SRM 53-2-0 FIG 1B. FABRICATED DOUBLER AND INSTALLED IAW SRM 53-2-0 FIG 1B. STATUS-CLOSED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C-CHECK - FWD CARGO COMPARTMENT - FLOOR SUPPORT ANGLE CRACKED 1/2 INCH AT STA 360.000 L-33R. PERFORMED STOP HOLE IAW SRM 53-2-0 FIG 1B. FABRICATED DOUBLER AND INSTALLED IAW SRM 53-2-0 FIG 1B. STATUS-CLOSED.