What was found
C-CHECK - MAIN CARGO COMPARTMENT. FLOOR SUPPORT U ANGLE CRACKED 1 INCH BL 0 STA 1734-1760. REMOVED CRACKED U ANGLE IAW SRM 51-1-20 PAGE 21. FABRICATED ANGLE IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED, AND PRIMED IAW SRM 51-1-8B. INSTALLED ANGLE IAW SRM 53-2-0 FIG 1B. STATUS-CLOSED.