What was found
C-CHECK - EXT FUSELAGE SKIN AT STA 1440.000 L-30 AND 31 RT SHOWS CRACK OF .5 INCH. REMOVED FASTENERS IAW SRM 51-1-21 PAGE 1. CUT OUT DAMAGED SKIN IAW EO DHL 010314, EO 2340, EO 2001095. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED FILLER AND DOUBLER (ALCLAD 7075 T6 0.071/0.080) IAW 010314, EO 2340, EO 2001095. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED FILLER AND DOUBLER WITH NEW FASTENERS IAW EO DHL 010314, EO 2340, EO 2001095, SRM 51-1-21 PAGE 1. APPLIED (PRC) SEALANT ON REWORKED AREA IAW SRM 51-1-15 PAGE 1.