What was found
C-CHECK - FWD CARGO COMPT. FITTING CRACKED 1/2 INCH AT STA 200 L26R. REMOVED CRACKED FITTING, CLEANED, TREATED AND PRIMED AREA AND INSTALLED NEW FITTING AT STA 200 L-26RH IAW SRM 51-3-0 PAGE 1, 2, SRM 51-1-8B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C-CHECK - FWD CARGO COMPT. FITTING CRACKED 1/2 INCH AT STA 200 L26R. REMOVED CRACKED FITTING, CLEANED, TREATED AND PRIMED AREA AND INSTALLED NEW FITTING AT STA 200 L-26RH IAW SRM 51-3-0 PAGE 1, 2, SRM 51-1-8B.