What was found
DENT .220 INCHES AT FRAME 32 LENGTH OF 8 INCHES FWD & 6 INCHES AFT OF FRAME 32 BETWEEN STRINGERS 28LT & 29 LT. PERFORM HFEC INSPECTION; STRINGER HOLES AND EDGE OF DAMAGE CUT OUT. REPAIRS WAS PERFORMED IAW SRM. PERFORM HFEC ON THE LE SKIN COMMON TO THE INBD END RIB IN REWORKED AREA (10-PCS-FASTENER HOLES) LT SIDE. REPAIR AT FUSELAGE FRAME 32 BETWEEN STRINGER 28 LT & 29 LT HAS BEEN PRIMERED BUT REQUIRES TO BE PAINTED.