What was found
BRAKE HOT LIGHT ILLUMINATED. ACCOMPLISHED ABNORMAL PROCEDURE PER AOM. RTO INFORMATION GOM 8.9 PG 13. WT. 305,000, OAT +5ØC, QNH 30.49. MAINTENANCE NOTED. SUSPECT PROBLEM WITH THE AUTO BRAKE SYSTEM. DEFERRED THE AUTO BRAKE SYSTEM IAW MEL 32-42-07. TESTED AUTO BRAKE SYSTEM PER A300 MM 32-42-54. SYSTEM OPS CHECKED SERVICABLE. THIS CLEARS DMI 11293.