Service difficulty report · Connector · Airbus A300B4203

Difficulty date
November 27, 2002
Submitted
December 2, 2002
Operation
Air carrier
Aircraft
N365DH
Make and model
Airbus A300B4203
Aircraft serial
149
Part
Connector
Condition
Damaged
Location
Mlg Temp Sensor
Stage of operation
TO
How discovered
O
Nature of condition
N
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RTO BECAUSE OF A HOT BRAKE LIGHT ILLUMINATED ON T/O. 305000 LBS., 70KTS., + 2 DEGREES C, BRAKE TEMPERATURE 190, INCREASED TO 270 AFTER ABORT. NR 4 WHEEL HOT PA-107. VISUALLY CHECKED NR 4 BRAKE FOUND OK. JACKED BRAKE UP FOUND OK. NO DRAGGING CLEANED AND RESEATED TEMPERATURE SENSOR CONNECTOR - MM 05-51-16.