What was found
DURING C CHECK, GOUGE IN FUSELAGE SKIN AT FS 1195 STR. 25 LT, CHEMICALLY REMOVED POINT FOR ACCESS IAW B-727 M/M 51-20-2. BLENDED GOUGE ON FUSELAGE SKIN IAW B-727 SRM 53-30-3 MEASURE DAMAGE AREA AS PER 51-30-1 FABRICATED DOUBLER FOR CUT-OUT IAW B-727 SRM 53-30-3. ALODINED AND PRIMED IAW B-727 SRM 51-10-2. INSTALLED COUNTERSINK REPAIR WASHED IAW B-727 SRM 51-30-8. INSTALLED DOUBLER REPAIR IAW B-727 SRM 53-30-3 FIG. 3 AND 51-30-2.