What was found
DURING C CHECK, SEVERAL GOUGES IN FUSELAGE SKIN FS 360 TO 380 STR. 18 LT. DAMAGE FOUND TO BE OUT OF LIMITS IAW B-727 SRM 53-30-3. REMOVED FASTENER AT FUSELAGE SKIN BS 360 TO 380 ABOVE STR 18 LT IAW B-727 SRM 51-30-2. CUT-OUT DAMAGED AREA IAW B-727 SRM 53-30-3. FABRICATED WASHER REPAIR IAW B-727 SRM 51-30-8. ALODINED AND PRIMED BARE METAL AND PARTS REPAIR IAW B-727 SRM 51-10-2. INSTALLED DOUBLER, FILLER AND WASHER REPAIR AT FUSELAGE SKIN 360 TO 380, STR 18 LT IAW B-727 SRM 53-30-3.